XW370K

SKU: XW370K

DIGITAL CONTROLLER WITH NT AND LT VENTILATED APPLICATIONS WITH "ON DEMAND" DEFROST, HEATER AND SHUTTER MANAGEMENT

Read more...

Specifications

Power supply
9÷40Vdc
Relay outputs
Compressor: 8A - Defrost: 8A - Fans: 8A - Heater control: 8A - Light: 8A - Shutter: 8A
Other
Hot Key / Prog Tool Kit output: present - Serial output: RS485 optional - Analog output: 4÷20mA optional - Buzzer: on keyboard
Power absorption
10VA max
Display
on keyboard 3 digits, red LED, 13,2mm high
Data storing
on the non-volatile memory (EEPROM)
Operating temperature
0÷60 °C
Storage temperature
-25÷60°C
Relative humidity
20÷85% (no condensing)
Measuring and regulation range
NTC probe: -40÷110°C
Resolution
0.1°C or 1°C
Accuracy (at ambient temperature)
±0.5°C ±1 digit
Generals
Keyboard: 6 push buttons (on T630)
Probe inputs
Thermostat: NTC - NT thermostat: NTC - Defrost: NTC - "on demand" defrost: NTC
Digital inputs
2 x configurable

Features

  • Possibility of controlling one LT and one NT compartment or one refrigerated and one heated compartment
  • "On demand” defrost for optimum defrost cycles management
  • Service hours count for system maintenance cycles
  • Thermostatic command for shutter opening
  • Hot Key for quick and easy programming
  • Serial connection to monitoring systems

Documents & Drawings

1
Product images shown are for illustration purposes only and may not be an exact representation of the product or package contents